(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
|
Tester Connection
|
Condition
|
Specified Condition
|
|
2 (RB) - 5 (PL)
|
Shift Position P
|
Below 1 Ω
|
|
2 (RB) - 5 (PL)
|
Shift Position Not P
|
10 kΩ or higher
|
|
2 (RB) - 1 (RL)
|
Shift Position R
|
Below 1 Ω
|
|
2 (RB) - 1 (RL)
|
Shift Position Not R
|
10 kΩ or higher
|
|
2 (RB) - 7 (NL)
|
Shift Position N
|
Below 1 Ω
|
|
2 (RB) - 7 (NL)
|
Shift Position Not N
|
10 kΩ or higher
|
|
2 (RB) - 6 (DL)
|
Shift Position D and S
|
Below 1 Ω
|
|
2 (RB) - 6 (DL)
|
Shift Position Not D and S
|
10 kΩ or higher
|
|
3 (B) - 4 (L)
|
Shift Position P and N
|
Below 1 Ω
|
|
3 (B) - 4 (L)
|
Shift Position Not P and N
|
10 kΩ or higher
|
If the result is not as specified, replace the switch.
|